MO-L011
Protein Labeling Kit RED-NHS 2nd Generation (Amine Reactive)
The Monolith Protein Labeling Kit RED-NHS 2nd Generation kit increases data quality and enables affinity studies with previously challenging targets by generating higher binding amplitudes and improved signal-to-noise ratios. It contains all required reagents for labeling and dye removal. The dye carries a reactive NHS-ester group that reacts with primary amines (lysine residues) to form a covalent bond. The kit is optimized for proteins with a molecular weight higher than 5 kDa and concentrations between 2 and 20 µM. RED dyes are suited for Monolith instruments with a RED detector (Nano and Pico) and Dianthus instruments.
MO-L014
Protein Labeling Kit RED-MALEIMIDE 2nd Generation (Cysteine reactive)
The Monolith Protein Labeling Kit RED-MALEIMIDE 2nd Generation kit increases data quality and enables affinity studies with previously challenging targets by generating higher binding amplitudes and improved signal-to-noise ratios. It contains all required reagents for labeling and dye removal. The dye carries a reactive maleimide group that reacts with cysteine residues to form a covalent bond. The kit is optimized for proteins with a molecular weight higher than 5 kDa and concentrations between 2 and 20 µM. RED dyes are suited for Monolith instruments with a RED detector (Nano and Pico) and Dianthus instruments.
MO-L018
His-Tag Labeling Kit RED-tris-NTA 2nd Generation
The Monolith His-Tag Labeling Kit RED-tris-NTA 2nd Generation kit increases data quality and enables affinity studies with previously challenging targets by generating higher binding amplitudes and improved signal-to-noise ratios. The kit is used for site-specific and purification-free labeling of His-tagged (6xHis) proteins and peptides. The kit can be used with purified as well as crude samples (e.g. cell lysate) and contains material sufficient for 500 single-point MST measurements. RED dyes are suited for Monolith instruments with a RED detector (Nano and Pico) and Dianthus instruments.
MO-L019
SNAP-Tag® Labeling Kit RED 2nd Generation
The SNAP-Tag® Labeling Kit RED 2nd Generation contains all required reagents for labeling and dye removal. The dye carries a benzylguanine group that reacts with the SNAP-tag® of your protein of interest to form a covalent bond. The kit is optimized for protein concentrations of 10 µM. Just like all of our 2nd Generation labeling kits, it increases data quality and enables affinity studies with previously challenging targets by generating higher binding amplitudes and improved signal-to-noise ratios. RED dyes are suited for Monolith instruments with a RED detector (Nano and Pico) and Dianthus instruments. Contents require storage at 4 °C and -20 °C.
NT-L111
Large Volume Protein Labeling Kit RED-NHS 2nd Generation (Amine Reactive)
This Large Volume Protein Labeling Kit RED-NHS 2nd Generation kit increases data quality and enables affinity studies with previously challenging targets by generating higher binding amplitudes and improved signal-to-noise ratios. It contains all required reagents for labeling and dye removal. The dye carries a reactive NHS-ester group that reacts with primary amines (lysine residues) to form a covalent bond. The kit is optimized for proteins with a molecular weight higher than 5 kDa and concentrations between 2 and 20 µM. RED dyes are suited for Monolith instruments with a RED detector (Nano and Pico) and Dianthus instruments. Contents require storage at 4 °C and -20 °C.
NT-L114
Large Volume Protein Labeling Kit RED-MALEIMIDE 2nd Generation (Cysteine reactive)
This Large Volume Protein Labeling Kit RED-MALEIMIDE 2nd Generation kit increases data quality and enables affinity studies with previously challenging targets by generating higher binding amplitudes and improved signal-to-noise ratios. It contains all required reagents for labeling and dye removal. The dye carries a reactive maleimide group that reacts with cysteine residues to form a covalent bond. The kit is optimized for proteins with a molecular weight higher than 5 kDa and concentrations between 2 and 20 µM. RED dyes are suited for Monolith instruments with a RED detector (Nano and Pico) and Dianthus instruments. Contents require storage at 4 °C and -20 °C.
NT-L118
Large Volume His-Tag Labeling Kit RED-tris-NTA 2nd Generation
This Large Volume His-Tag Labeling Kit RED-tris-NTA 2nd Generation kit increases data quality and enables affinity studies with previously challenging targets by generating higher binding amplitudes and improved signal-to-noise ratios. The kit is used for site-specific and purification-free labeling of His-tagged (6xHis) proteins and peptides. The kit can be used with purified as well as crude samples (e.g. cell lysate) and contains material sufficient for 3840 single-point MST measurements. RED dyes are suited for Monolith instruments with a RED detector (Nano and Pico) and Dianthus instruments. Store at -20 °C.
NT-L020
Biotinylated Target Labeling Kit
The Biotinylated Target Labeling Kit is used for the site-directed labeling of any protein or peptide carrying one or multiple biotin tags. It contains material sufficient for labeling 500 single-point spectral shift measurements. The kit includes a protocol for labeling in 15 min with no removal of excess dye required. The Biotinylated Target Labeling Kit is suited for use with Monolith X and Dianthus with Spectral Shift. Contents require storage at -20 °C.
NT-L120
Large Volume Biotinylated Target Labeling Kit
The Large Volume Biotinylated Target Labeling Kit is used for the site-directed labeling of any protein or peptide carrying one or multiple biotin tags. It contains material sufficient for labeling 4,000 single-point spectral shift measurements. The kit includes a protocol for labeling in 15 min with no removal of excess dye required. The Large Volume Biotinylated Target Labeling Kit is suited for use with Monolith X and Dianthus with Spectral Shift. Contents require storage at -20 °C.
NT-L030
Small Volume Human Fc Labeling Kit
The Small Volume Human Fc Labeling Kit provides a convenient means for the site-specific, purification-free labeling of humanized antibodies or antibody fragments containing the Fc region with fluorescent dye optimized for affinity measurements done with Spectral Shift technology. The kit is used for the site-directed labeling of any protein carrying a Human Fc antibody region. It contains material sufficient for labeling for 500 single-point Spectral Shift measurements. The kit includes a protocol for labeling in <30 min; no removal of excess dye required. The Small Volume Human Fc Labeling Kit is suited for use with Monolith X and Dianthus with Spectral Shift. Contents require storage at -20 °C.
NT-L130
Large Volume Human Fc Labeling Kit
The Large Volume Human Fc Labeling Kit provides a convenient means for the site-specific, purification-free labeling of humanized antibodies or antibody fragments containing the Fc region with fluorescent dye optimized for affinity measurements done with Spectral Shift technology. The kit is used for the site-directed labeling of any protein carrying a Human Fc antibody region. It contains material sufficient for labeling for 4,000 single-point Spectral Shift measurements. The kit includes a protocol for labeling in <30 min; no removal of excess dye required. The Large Volume Human Fc Labeling Kit is suited for use with Monolith X and Dianthus with Spectral Shift. Contents require storage at -20 °C.
NT-B001
Buffer Exploration Kit
Your mission is to find the right buffer conditions for biophysical interaction assays, protein stability, purification, and storage. This kit will help you with your MST and TRIC assay development. Start your buffer exploration with this 96 deep-well plate containing 1 mL of each buffer condition per well.
MO-X001
Monolith Explorer Kit – Mission to Mars
The goal of this mission is to get your assay development going. We’ve packed everything you’ll need to perform one independent labeling reaction for proteins and peptides with RED-NHS and RED-tris-NTA 2nd Generation dyes. Includes dyes, dye removal reagents, and 60 premium capillaries. Store contents at room temperature, 4 °C and -20 °C as required.
DI-P001A
Dianthus 384-well plate, barcoded – Single plate
Single 384-well barcoded plate for TRIC measurement with Dianthus system. Hard sided, black/black with clear bottom, 18-25 μL working volume.
DI-P001B
Dianthus 384-well plates, barcoced – Package of 10
Rack of 10 384-well barcoded plates for TRIC measurement with Dianthus system. Hard sided, black/black with clear bottom, 18-25 μL working volume.
DI-P001C
Dianthus 384-well plates, barcoded – Package of 40
Four racks of 10 384-well barcoded plates for TRIC measurement with Dianthus system. Hard sided, black/black with clear bottom, 18-25 μL working volume.