Knowing the strength of the interactions between key players will give you the insights you need to understand the details behind how biological systems work.

 

If you’re having difficulty studying challenging interactions that include membrane proteins, PROTACs, intrinsically disordered proteins (IDPs), or RNA-based therapeutics, you’ll need Monolith to characterize them.

Monolith measures the broadest range of binding affinities in-solution, using very little sample


Measure high and low affinities in the same instrument

Different projects have different demands. It’s inevitable that you’ll need to look at both weak and strong molecular interactions. With a broad sensitivity range, Monolith measures Kds varying from pM to mM, so you can tackle as many projects as you want.


Characterize binding events with very little sample

It’s not easy to prepare the large volumes of highly concentrated target and ligand required by ITC. With Monolith, you get a Kd in a fraction of the volume and concentration, leaving you with more sample for additional experiments.


Measure in solution, in close-to-native conditions

Immobilizing molecules in SPR assays often causes them to lose activity, and you’re left without results. Because Monolith measures in solution in most buffers, both binding partners are free to interact in their native conformation, you’ll finally get results.

Characterize interactions with many different types of molecules or samples

You know what types of interactions you need to characterize now, but it’s always difficult to predict what you’ll need to look at in the future. Monolith gives you one less thing to worry about because it has the flexibility to handle all different types of molecules and samples.

 


Proteins
Membrane proteins, intrinsically disordered proteins (IDPs), receptors, enzymes, antibodies, and nanobodies


Small molecules
Fragments, PROTACs, ions, nanoparticles, peptides, and carbohydrates


Nucleic acids
DNA, RNA, and aptamers


Vesicles
Exosomes and liposomes


Platelets and whole cells


Virus particles and empty capsids

Evaluate more than a binary interaction

 

競⁠合⁠ア⁠ッ⁠セ⁠イ
同⁠じタ⁠ー⁠ゲ⁠ッ⁠ト⁠に対⁠す⁠る2⁠つ⁠以⁠上⁠の分⁠子⁠の相⁠対⁠的⁠な親⁠和⁠性⁠を評⁠価⁠す⁠る

三⁠項⁠結⁠合⁠イ⁠ベ⁠ン⁠ト
3⁠つ⁠以⁠上⁠の結⁠合⁠パ⁠ー⁠ト⁠ナ⁠ー⁠が関⁠与⁠す⁠る相⁠互⁠作⁠用⁠を特⁠徴⁠付⁠け⁠ま⁠す

Derive additional information from your affinity assays

 

Oligomerization and aggregation
Monitor these events to understand protein functionality

化学量論*
結⁠合⁠パ⁠ー⁠ト⁠ナ⁠ー⁠の分⁠子⁠比⁠を算⁠出⁠す⁠る

熱力学*
算⁠出⁠さ⁠れ⁠た K d か⁠ら ∆G、∆H、お⁠よ⁠び ∆S を導⁠き⁠出⁠す

 

*Monolith ソ⁠フ⁠ト⁠ウ⁠ェ⁠ア⁠でサ⁠ポ⁠ー⁠ト⁠さ⁠れ⁠て⁠い⁠な⁠いオ⁠フ⁠ラ⁠イ⁠ン⁠デ⁠ー⁠タ⁠処⁠理⁠が必⁠要

Use MST technology to measure interactions

Monolith uses MST technology to quantify molecular interactions between a target and ligand by detecting changes in fluorescence intensity while a temperature gradient is applied over time (grey box, top figure). The fluorescent signal comes from the target that is either fluorescently labeled or has intrinsic fluorescence and becomes an extremely sensitive reporter for the interaction. The binding affinity is automatically determined at the end of each run without additional and lengthy data analysis. The affinity constant (Kd) is calculated from a fitted curve that plots normalized fluorescence against concentration of ligand (bottom figure).


Monolith has no fluidics — that means there’s really no regular maintenance

Life is so much easier when fluidics aren’t involved. Monolith doesn’t require cleaning or flushing in between runs, or a maintenance contract. So, it’s ready whenever you’re ready.

Monolith Pico


The best choice for studying interactions spanning a broad range of sensitivity. Turn pico mode on to measure very strong interactions, or off for weak ones.

Monolith


Choose this if you want the most flexibility when it comes to labeling strategies. Pick the two fluorescent channels you need the most.

Monolith LabelFree


When you want to measure interactions by detecting the intrinsic fluorescence of your target protein, choose this.

Read about the upgrades from the original Monolith NT.115

 

Learn more

As interactions are characterized free in solution, MST has been successful where SPR failed due to the limitations of a surface-based approach.

Dr. Stephan Uebel
Max-Planck-Institute of Biochemistry, Germany

 

お客様の声

Feel confident your experiments will run smoothly with software that’s smart

 

   MO.Control 2

Most software starts once you load your samples and start your run. Monolith’s MO.Control is built differently — not only do you get help with guided step-by-step experimental planning and assay setup before you start your run, but you also get immediate feedback on assay optimization based on your results after the run is over. MO.Control 2 adds the ability to optimize buffer conditions more efficiently so you can get to generating results faster.

 


 

   MO.Affinity Analysis 3

Make sure your analysis is consistent across various data sets and that you’re identifying any insights across replicate measurements. MO.Affinity Analysis 3 is the ideal complement to MO.Control 2 — merge and group your data sets for comparison purposes and then easily report results with presentation-worthy data and publication-ready figures.

Get great results with tailor-made consumables

Monolith Capillary Trap

Monolith capillaries are made with care — they’re manufactured in a state-of-the-art facility and rigorously tested. Pair the capillaries with one of the Monolith Protein Labeling Kits to get the highest quality data and ultimately, the best outcome with Monolith.

Monolith Kit Contents

Spend less time optimizing your assay and more time getting actionable results

 

Spending time and money just optimizing assays and not generating usable data is super-frustrating, especially when you have limited resources. Monolith has ways to help you start with the target labeling step, and with optimizing your assays conditions so you can get to actionable results sooner.

 


Your success starts with choosing the right labeling strategy
The online and interactive Protein Labeling Assistant gives you the best labeling recommendations for your target protein and your instrument optics.


Feel confident you have the right buffer conditions
MO.Control 2 software makes it super easy to check the effects of buffers on your interactions. Take advantage of the ability to run 24 capillaries to screen up to 6 different buffer conditions in duplicates and with no-ligand controls in the same run. Read the technical note for an example of how easy it is to find the right buffer conditions.


Find the optimal buffer conditions in less time
Use the Buffer Exploration Kit, a 96-well plate loaded with ready-to-use buffers commonly used in MST assays so you don’t have to pre-mix them yourself. It makes buffer screening less time-consuming.


Get instant quality checks
Key quality parameters such as aggregation, photobleaching, and low signal-to-noise are constantly monitored for you. If additional optimization is necessary, you’ll get recommendations on how to correct these issues.

Do you want to learn about the original Monolith NT.115?

 

Find out more

Want to learn more about Monolith?

View Brochure     Contact Specialist

汉语日本語English